Details
Product: Ensim Pro for Windows 20003
Version: 4.0.0
Date : 01/12/05
Description: Fixes defect "UPDATE ORG/ udating site with features"
Cause: Config type system.int64 was not handled through CLI update code.
Download: ftp://ftp.ensim.com/outgoing/kb/windows/4.0.0/hotfix3/wwpcli.dll
Md5sum: 19eaa8e4a3a26a844579a3f79f6537f4
Installation Procedure.
On the server where Ensim Pro 4.0 is installed:
File to patch: wwpcli.dll
Note: It is assumed that <install_dir> refers to the path where Ensim Pro is installed. For example, if Ensim Pro is installed in : C:\Program Files\Ensim\WEBppliance
then this path is <install_dir>
1. Login to the server
2. Stop EnsimProvisionEngine
Goto Programs->Administrative Tools->Component Services.
Expand Component Services->My computer->COM+ Application
Right click on EnsimProvisionEngine and select shutdown.
3. Goto <install_dir>\cli
4. Backup existing wwpcli.dll to some other place
5. Replace wwpcli.dll with the version located at the same location from where you are reading this file.
6. Start EnsimProvisionEngine
Goto Programs->Administrative Tools->Component Services.
Expand Component Services->My computer->COM+ Application
Right click on EnsimProvisionEngine and select start.
7. Do iisreset.
Go to Command prompt (Start >> Run >> type cmd and press enter) at command prompt type "iisreset"
|