Details
Ensim®Pro for Windows 4.0.0 Patch 5 Release notes
Patch information
- Product: Ensim Pro for Windows - 4.0.0
- Patch Number: 5
- Date: May 2 2005
Supported version
- Ensim Pro for Windows: 4.0.0
Installation Prerequisites
- Ensim Pro for Windows 4.0.0 - patch 1, 2, 3, 4
Downloadftp://ftp.ensim.com/outgoing/kb/windows/4.0.0/hotfix5/WWP-4.0.0-Hotfix-5.zip
Md5sum: a6d61351193e5d7f39b0ae02035ccb30
Installation instructions
Installing the patch on server
Complete the following steps on server:
- Login to the server as administrator.
- Open a command window and run the command iisreset /stop
- Stop the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Shut Down
- Open command shell and switch to <install_dir>\pe\ProvEngine directory where <install_dir> refers to the path where Ensim Pro is installed. For example, if Ensim Pro is installed in C:\Program Files\Ensim\WEBppliance, then switch to C:\Program Files\Ensim\WEBppliance\pe\ProvEngine directory.
- Backup Ensim.ProvEngine.dll at some other place say C:\beforehotfix5\Ensim.ProvEngine.dll
- Replace Ensim.ProvEngine.dll in the current directory with Ensim.ProvEngine.dll packaged in this patch.
- Start the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Start
- Open a command window and run the command iisreset /start
Rollback instructions
Rollback of the patch on server
- Login to the server as administrator.
- Open a command window and run the command iisreset /stop
- Stop the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
Navigate to : Computers > My Computer > COM+ Application > EnsimProvision Engine. Right Click > Shut Down
- Open command shell and switch to <install_dir>\pe\ProvEngine directory where <install_dir> refers to the path where Ensim Pro is installed. For example, if Ensim Pro is installed in C:\Program Files\Ensim\WEBppliance, then switch to C:\Program Files\Ensim\WEBppliance\pe\ProvEngine directory.
- Copy C:\beforehotfix5\Ensim.ProvEngine.dll to current directory
- Start the EnsimProvision Engine COM+ component. Open Start > Program > Administrative Tools > Component Services
Navigate to : Computers > My Computer > COM+ Application > EnsimProvisionEngine. Right Click > Start
- Open a command window and run the command iisreset /start
|